The Centurion LiFePO4 features true online double conversion. As our highest single phase power density UPS, this sophisticated range will provide the most comprehensive protection for mission critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications. Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion RT addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology.
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
The Centurion LiFePO4 features true online double conversion. As our highest single phase power density UPS, this sophisticated range will provide the most comprehensive protection for mission critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications. Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion RT addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology.
| HID | Supports Windows, Apple, Linux, NAS and various industrial controllers |
|---|---|
| Phase | Single phase with ground |
| Battery | LiFePO4 |
| Humidity | 20–90% (RH Non-condensing) |
| Software | PowerShield® NetGuard® software – supports Windows, Linux, Unix and Mac based operating systems |
| Topology | True online double-conversion |
| Waveform | Pure Sine Wave |
| Capacity | 1000VA/900W |
| Interface | USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact |
| AU Outlets | 3 |
| IEC Outlets | 10A, C13 x 5 |
| Noise Level | < 50dBA @ 1 Meter |
| Temperature | 0–40°C |
| Weight (kg) | 10.2 |
| Battery Mode | 87% |
| Audible Alarm | Battery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload |
| Frequency Range | 40Hz–70Hz |
| Full Protection | Overload, discharge, thermal, short circuit and overcharge protection |
| Surge Protection | 1872 Joules / 39000 Amps |
| High Line Comeback | 290VAC ± 5 % |
| High Line Transfer | 300VAC ± 5 % |
| Inverter to Bypass | 4ms (Typical) |
| LCD Display/ Alarm | UPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators |
| ECO Mode (Advanced) | 96% |
| Output Power Factor | 0.9 |
| Typical Recharge Time | 2 hours |
| Dimension (Dx Wx H) mm | 380 x 438 x 88 |
| Power Factor Correction | 0.99 @ nominal voltage (100% load) |
| Output Voltage (AC Mode) | 240VAC (Selectable 200/208/220/230/240VAC) |
| Frequency Range (Batt Mode) | 50Hz or 60Hz ±1Hz |
| Voltage Regulation (Batt Mode) | ± 1% |
| Voltage Range- Low Line Comeback | 175Vac / 155VAC / 135VAC / 125VAC ± 5 % |
| Voltage Range- Low Line Transfer | 160Vac / 140Vac / 120 / 110VAC ± 5 % (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0) |
Product information source: Dicker Data Partner Portal.